Devices that use the dh-485 network – Rockwell Automation 1747-L40 SLC 500 Fixed Hardware Style User Manual

Page 108

Advertising
background image

Appendix A
Setting Up the DH-485 Network

A–3

Presently, the following SLC 500 devices support the DH–485 network:

SLC 500 Fixed I/O Controller (responder)

SLC 5/01 Modular I/O Controller (responder)

SLC 5/02 Modular I/O Controller (initiator/responder)

SLC 5/03 Modular I/O Controller (initiator/responder)

Personal computer running SLC 500 Advanced Programming Software
(initiator)

Hand–Held Terminal (initiator)

DTAM (initiator/responder)

Other devices that use the DH–485 network include those in the table below.

Catalog Number

Description

Installation Requirement

Function

Publication

1746-BAS

BASIC Module

SLC Chassis

Provides an interface for SLC 500

devices to foreign devices. Program in

BASIC to interface the 3 channels (2

RS-232 and 1 DH485) to printers,

modems, or the DH-485 network for

data collection.

1746-ND005
1746-NM002
1746-NM001

1747-KE

DH-485/DF1

Interface Module

SLC Chassis

Provides a non-isolated DH-485

interface for SLC 500 devices to host

computers over RS-232 using full- or

half-duplex DF1 protocol. Enables

remote programming with APS to an

SLC 500 processor or the DH-485

network through modems. Ideal for low

cost RTU/SCADA applications.

1747-NU001

1770-KF3

DH-485/DF1

Interface Module

Standalone (desktop")

Provides an isolated DH-485 interface

for SLC 500 devices to host computers

over RS-232 using full- or half-duplex

DF1 protocol. Enables remote

programming with APS to an SLC 500

processor or the DH-485 network

through modems.

1770-6.5.18

1784-KR

PC DH-485

Interface Module

IBM XT/AT

Computer Bus

Provides an isolated DH-485 port on the

back of the computer. When used with

APS software, it improves

communication speed and eliminates

use of the Personal Interface Converter

(1747-PIC). The Standard Driver allows

you to write C" programs for data

acquisition applications.

1784-2.23
6001-6.5.5

1785-KA5

DH

+

t

/DH485

Gateway

(1771) PLCr Chassis

Provides communication between

stations on the PLC-5 (DH

+

) and SLC

500 (DH-485) networks. Enables

communication and data transfer from

PLC to SLC 500 on DH-485 network.

Also enables APS programming or data

acquisition across DH+ to DH-485.

1785-6.5.5
1785-1.21

2760-RB

Flexible Interface

Module

(1771) PLC Chassis

Provides an interface for SLC 500 (using

protocol cartridge 2760-SFC3) to other

A-B PLCs and devices. Three

configurable channels are available to

interface with Bar Code, Vision, RF,

Dataliners, and PLC systems.

2760-ND001

Devices that Use the DH-485