7 - maintaining your control system, Handling, Storing – Rockwell Automation 1747-L40 SLC 500 Fixed Hardware Style User Manual

Page 86: Maintaining your control system

Advertising
background image

7

Chapter

7–1

Maintaining Your Control System

This chapter covers the following:

handling, storing, and transporting battery, Catalog Number 1747–BA

installing or replacing your SLC 500 battery

replacing the power supply fuse

replacing retainer clips on a module

Refer to chapter 2 for important information on testing the master control
relay circuit and preventive maintenance.

Follow the procedure below to ensure proper battery operation and reduce
personnel hazards.

Handling

Use only for the intended operation.

Do not ship or dispose of batteries except according to recommended
procedures.

Do not ship on passenger aircraft.

!

ATTENTION: Do not charge the batteries. An explosion could
result or they could overheat causing burns.

Do not open, puncture, crush, or otherwise mutilate the batteries.
A possibility of an explosion exists and/or toxic, corrosive, and
flammable liquids would be exposed.

Do not incinerate or expose the batteries to high temperatures.
Do not attempt to solder batteries. An explosion could result.

Do not short positive and negative terminals together. Excessive
heat could build up and cause severe burns.

Storing

Store the lithium batteries in a cool, dry environment, typically +20

°

C to

+25

°

C (+68

°

F to +77

°

F) and 40% to 60% relative humidity. Store the

batteries and a copy of the battery instruction sheet in the original container,
away from flammable materials.

Handling, Storing, and

Transporting Battery, Catalog

Number 1747-BA

Advertising