2-12 Install the Module

Assemblies

The Encoder and Counter Module uses several words to communicate real-time
input and output data as well as non-real-time module information (for example,
description, revision, etc.) and configuration. This shows the words that you can
exchange. You can read (get) or write (set) data using an Explicit Message.

Instance Services

Field

Bytes

#101 (0x65)

Get

Present Channel Data

4

Status

2

#102 (0x66)

Get

Stored Channel Data

4

Status

2

#103 (0x67)

Get

Present Channel Data

4

Stored Channel Data

4

Status

2

#104 (0x68)

Get

Programming Error Code

2

#105 (0x69)

Set/Get

Counter Control

1

#106 (0x6a)

Set/Get

Counter Configuration

1

Filter Selection

1

Decimal Position

1

Reserved

1

Time Base

2

Gate Interval

1

Scalar

1

Rollover Value

4

Preset Value

4

Counter Control SSV

1

#123 (0x7b)

Set/Get

Counter Configuration

1

Filter Selection

1

Decimal Position

1

Reserved

1

Time Base

2

Gate Interval

1

Scalar

1

Rollover Value

4

Preset Value

4

Counter Control SSV

1

Alignment (reserved = 0)

1