Input and Output Data

That This Chapter Contains

Read this chapter to learn about the input/output data table of your
1734-IJ and 1734-IK.

Data Table

See the table for a complete format of the input/output data..

For more information about:

See page:

Data Table

3-1

Detailed Description of Data Table Information

3-2

Configuration Data

3-4

Communicate Real Time/Nonreal Time Information

3-8

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

0

Input Information

Present Channel Data

32-bit Value of the present counter state

Stored Channel Data

32-bit value of the stored/accumulated count

Status

PE

EF

NR

0

0

0

0

0

0

ZS

BS

AS

C1

C0

ZD

0

Programming Error Code

PE

0

0

0

0

E10

E9

E8

E7

E6

E5

E4

E3

E2

E1

E0

Output Information

Counter Control

0

0

0

0

0

VR

CP

CR

Configuration Information

Counter Configuration

ZI

MD

MD

MD

CF

CF

CF

CF

Filter Selection

0

ZF

BF

AF

FS

FS

FS

FS

Decimal Position

8-bit value used to modify the present channel data display

Reserved

Time Base

16-bit value used to set the time base

Gate Interval

8-bit value used to set the gate interval

Scalar

8-bit value used to divide the Z input by 2

n

Rollover Value

32-bit value at which the counter is commanded to rollover

Preset Value

32-bit value the counter is to be set to when CP is asserted

Counter Control SS Value

0

0

0

0

0

VR

CP

CR