Rockwell Automation 1734-IK Encoder/Counter Modules User Manual User Manual

Page 60

Advertising
background image

Publication 1734-UM006B-EN-P - August 2005

A-6 Configure Modules in RSLogix 5000 Software

3. Refer to the table to make selections for the following entries.

• Store Count Mode
• Rollover
• Preset
• Counter Attenuator
• Frequency Precision
• Gate Multiplier
• Time Base
• Actual Gate Interval

If You Selected This for Type For This Value

Select

Comments

Counter (default)
Encoder X1
Encoder X2
Encoder X4

Store Count
Mode

Store Count Disabled
Store-Continue
Store-Wait-Resume
Store, Reset-Wait-Start
Store, Reset-Start

Default is Store Count Disabled.
Select an option to determine which mode you use
for operating the Z Gate/Reset Terminal,

Rollover

1 to 16777216

Default is 16777215.
Select a value greater than the value for Preset.

Preset

0 to 16777215

Default is 0.
Select a value smaller than the value for Rollover.

Counter
Attenuator

0 to 255

Default is 1.
Select a value to attenuate the counter display.

Period/Rate
Rate Measurement

Frequency
Precision

X 0.0001
X 0.001
X 0.01
X 0.1
X 1
X 10
X 100

Default is X1.
Select a value to multiply the frequency by the factor
selected.

Gate Multiplier

1 to 200

Default is 1.
Select a value so that the product of Gate Multiplier
and Time Base does not exceed 3 seconds
(3000 milliseconds).

Time Base

10 to 3000 milliseconds
in multiples of 10

Default is 1000.

Actual Gate
Interval

You do not make a
selection, as this is a static
field you do not configure.

This is the product of Gate Multiplier and Time Base.
An acceptable value is less than 3 seconds
(3000 milliseconds).