Rockwell Automation 1734-IK Encoder/Counter Modules User Manual User Manual

Page 61

Advertising
background image

Publication 1734-UM006B-EN-P - August 2005

Configure Modules in RSLogix 5000 Software A-7

4. For Filter, select the Frequency from the following, which is the

value you use to filter A/B/Z inputs when you check a
corresponding checkbox.

• No Filter
• 50 kHz
• 5 kHz
• 500 Hz
• 50 Hz (default)

5. Check the checkboxes for the following, which use the value

you selected for Filter.

• Filter A
• Filter B
• Filter Z

6. For Invert, check the checkbox to invert the signal at Z input, if

you selected the following for Type.

• Counter
• Encoder X1, Encoder X2, or Encoder X4
• Period/Rate

7. For Scalar, if you selected Period/Rate, choose one of the

following values.

• 1
• 2
• 4
• 8
• 16
• 32
• 64
• 128

If you apply the filter, you scale the filtered Z. The value you
chose for Scalar scales the Z signal for the following
configurations.

• Period/Rate
• Continuous/Rate
• Pulse Generator

Advertising
This manual is related to the following products: