Installation precautions, Environment and enclosure information, European union compliance – Rockwell Automation 6180P-xxxx Integrated Display Computers with Keypad User Manual User Manual

Page 18

Advertising
background image

18

Rockwell Automation Publication 6180P-UM001C-EN-P - February 2014

Chapter 2

Installation

Installation Precautions

Read and follow these precautions before installing the computer.

Environment and Enclosure Information

European Union Compliance

This computer meets the European Union Directive requirements when installed
within the European Union or EEA regions and have the CE mark. A copy of the
declaration of the conformity is available at

http://www.rockwellautomation.com/

certification

.

ATTENTION: This equipment is intended for use in a Pollution Degree 2
environment, in overvoltage Category II applications (as defined in IEC 60664-1),
at altitudes up to 2000 m (6562 ft) without derating. The enclosure door must
be closed.

This equipment is considered Group 1, Class A equipment according to IEC/CISPR 11.
Without appropriate precautions, there can be potential difficulties ensuring
electromagnetic compatibility in other environments due to conducted as well as
radiated disturbance.

This equipment can be mounted in an enclosure that is suitably designed to
prevent personal injury resulting from accessibility to live parts. If not mounted
inside another enclosure, the mounting method must limit the tilt of the computer
to +/- 30° from vertical. Examples include articulated arm, table-top stand, wall
mount, or other means having sufficient mechanical stability. The mounting
means must be firmly attached to the supporting surface using screws bolts, or
clamps so the computer cannot tip.

In addition to this publication, see the following:

Industrial Automation Wiring and Grounding Guidelines, publication

1770-4.1

,

for additional installation requirements

NEMA 250 and IEC 60529, as applicable, for explanations of the degrees of

protection provided by different types of enclosure

ATTENTION: This computer is intended to operate in an industrial or control
room environment, which uses some form of power isolation from the public
low–voltage mains. Some computer configurations cannot comply with the
EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of
the European Union. Obtain permission from the local power authority before
connecting any computer configuration that draws more than 75 W of AC power
directly from the public mains.

To comply with EN 55024, the Ethernet port LAN cable 30 m (98.42 ft), only used
indoors, and not exit the building at any point. All other I/O cables must be less
than 3 m (9.84 ft) and only used indoors.

Advertising