Functional ground screw – Rockwell Automation 6180P-xxxx Integrated Display Computers with Keypad User Manual User Manual

Page 27

Advertising
background image

Rockwell Automation Publication 6180P-UM001C-EN-P - February 2014

27

Installation

Chapter 2

Follow these steps to connect the computer to a DC power source.

1. Turn off the main power switch or breaker.

2. Verify that the DC wires meet these requirements:

Material: Stranded copper
Wire gauge: 0.325…0.823 mm

2

(22…18 AWG)

3. Secure the DC power wires

to the correct terminal-
block screws, and the DC
ground wire to the GND
terminal screw.

Torque the terminal screws
to 0.687 N•m (6.1 lb•in).

4. Apply 24V DC power to the

computer.

Functional Ground Screw

The pre-installed functional ground screw is not required for safety or regulatory
compliance. However, if a supplemental ground is desired, use the functional
ground screw located in the I/O area on the side panel of the computer.

If using the functional ground screw, connect the computer to earth ground by
using a 1.5 mm

2

(16 AWG) or larger external wire. Use a ground wire with green

insulation and a yellow stripe for easy identification.

Pre-installed DC

Ground Bus Strip

+v -v GND

Side View

Advertising