Installing the converter -2, 2 installing the converter – Rockwell Automation 1203-USB USB Converter (Same as DRIVES-UM001) Out of synch with AB version. User Manual

Page 14

Advertising
background image

3-2

USB Converter User Manual

Important: The MDI cable shield must be properly grounded to provide EMC

protection. On a MD60 drive, Pin 16 of the drive control terminal block
must be connected to the drive earth ground terminal.

3.2

Installing the Converter

Important: The converter must not be installed in an area where the ambient

atmosphere contains volatile or corrosive gas, vapors or dust. If the
converter is not going to be installed for a period of time, it must be stored
in an area where it will not be exposed to a corrosive atmosphere.

1.

Connect the converter to the drive (

Figure 3.3

) using the appropriate cable

Table 3.1 – Cable Descriptions (DPI)

Item

Description

Catalog Number

DPI cable to connect the converter to a
DPI drive.

20-OIM-HIO

USB cable to connect the converter to
the computer.

Figure 3.2 – Cables for Connecting to a MDI Drive and Computer

Table 3.2 – Cable Description (MDI)

Item

Description

Catalog Number

MDI cable to connect the converter to a
MDI drive.

22-OIM-HIO

USB cable to connect the converter to
the computer.

Advertising