Rockwell Automation 1203-USB USB Converter (Same as DRIVES-UM001) Out of synch with AB version. User Manual

Page 30

Advertising
background image

5-2

USB Converter User Manual

!

ATTENTION: Risk of injury or equipment damage exists. If the converter
is transmitting control I/O to the drive (indicated by a solid green diamond
LED), the drive may fault when you remove or resetthe converter.
Determine how your drive will respond before removing or resetting a
converter.

Table 5.2 – Diamond Status Indicator

Status

Cause

Corrective Action

Off

Converter is not powered or is
in Flash programming mode.

Securely connect cables.

Apply power to the drive.

Wait until Flash update is
completed.

Flashing
Green

Converter is operating and
not transmitting control I/O.

No action required. Removing or
resetting the converter will not
cause a fault in the drive.

Solid
Green

Converter is operating and is
or was transmitting control
I/O.

No action required. Removing or
resetting the converter will cause a
fault in the drive.

For DPI drives only, a “Soft Logout”
can be performed to allow removal
of the converter without a fault
occurring. To do this, set the logic
mask in the drive to ignore the
converter and then verify that the
drive is receiving its Logic
Command and Reference from
another source.

Flashing
Red

The drive has not
acknowledged the converter.

Securely connect cables.

DPI Drives: Verify that converter
parameter Interface Mode (06)
is set to “Auto.”

MDI Drives: Verify that
converter parameter Adapter
Cfg (01)
is set to “Auto.”

The drive was disconnected
from the computer, or the
computer was turned off.

Securely connect cables.

Turn on the computer.

Solid Red

Link failure.

Securely connect cables.

Replace the cable.

Cycle power to the drive.

Advertising