B-2

USB Converter User Manual

03

Clear DF1 Counts
No action if set to “Ready.” Resets the
DF1 statistical parameter DF1 Packets
Sent (04)
and DF1 Packets Rcvd (05) to
0 if set to “Clear Counts.” This parameter
is a command. It will be reset to “0 =
Ready” after a “Clear Counts” command
has been performed.

Default:

0 = Ready

Values:

0 = Ready
1 = Clear Counts

Type:

Read/Write

Reset Required:No

04

DF1 Packets Sent
Displays the number of DF1 packets sent
by the converter. The value of this
parameter is normally approximately
equal to the value of DF1 Packets Rcvd
(05)
.

Default: 0

Minimum:0

Maximum:4294967295

Type:Read Only

05

DF1 Packets Rcvd
Displays the number of DF1 packets
received by the converter. The value of
this parameter is normally approximately
equal to the value of DF1 Packets Sent
(04)
.

Default: 0

Minimum:0

Maximum:4294967295

Type:Read Only

06

Interface Mode
Sets the interface operating mode:

Auto: The converter will automatically run
DPI if connected to a DPI drive.

Set this parameter to “Auto” (default).

Default:

0 = Auto

Values:

0 = Auto
1 = SCANport

Type:

Read/Write

Reset Required:Yes

07

DPI Data Rate
Displays the data rate used by the DPI
host drive. This data rate is set in the
drive, and the converter autobauds to it.

Default:

0

Values:

0 = 125 kbps
1 = 500 kbps

Type:

Read Only

08

Ref/Fdbk Size
Displays the size of the
Reference/Feedback. The host drive
determines the size of the
Reference/Feedback. The converter
automatically uses the correct size.

Default:

0 = 16-bit

Value:

0 = 16-bit
1 = 32-bit

Type:

Read Only

09

Datalink Size
Displays the size of each Datalink word.
The host drive determines the size of
Datalinks.

Default:

0 = 16-bit

Values:

0 = 16-bit
1 = 32-bit

Type:

Read Only

No.

Name and Description

Details