Confirmations This section contains the table providing the details

for all confirmations available in the database.

Date/Time This column represents the dates and times at which

field confirmations were performed.

Method This column represents the type of confirmations

performed. Q represents a quantity confirmation (such as a weir);
V represents a velocity/depth confirmation.

Depth This column represents the manual depth measurements

taken at the monitoring point (+/- represents the margin of error of
the depth measurement).

Average Velocity This column represents the average velocities

determined based on the manual peak velocity measurements taken
at the monitoring point and the Average-to-Peak ratios (+/-
represents the margin of error of the peak velocity measurement).

Quantity This column represents the manual quantity

measurements taken at the monitoring point (+/- represents the
margin of error of the quantity measurement).

Calculated Quantity This column represents the quantities

calculated using the confirmation information.

Working with Flow Monitor Adjustment Factors

IntelliServe can apply multipliers called adjustment factors to DPROCESSED,
QFINAL, QGROSS, and VPROCESSED values when generating graphs and
reports. Adjustment factors are created or modified by a user (with the
appropriate permissions) or an administrator for individual flow monitor
locations at the parameter level. You can create factors for up to all four entities,
and each location can have multiple factors associated with a single entity based
on designated dates on which the factors are applied.

The following sections provide instructions on viewing, creating, and deleting
adjustment factors.

Viewing Flow Monitor Adjustment Factors

View the adjustment factors for a specific flow monitor location from the Flow
Monitor Adjustment Factors
window in the following way:

1. Select Locations > Flow Monitors from the System Menu.