h2000 Autopilot User Manual
Part 4 - Installation Information

HB-0842-04

4-4

All cables should be routed at least 1m/3ft from cables or
components that carry or generate high currents, e.g. alternators,
starter motors and cabling, trim-tab cables, etc.

To minimise interference avoid routing Network cables alongside
high power radio or Radar cables, allow 3m/10ft spacing, or within
1m/3ft of engine starter motors and cables and other cables
carrying heavy current.

To prevent damage to cabling always secure in position using
cable clips or tie-wraps. Where cables pass through bulkheads
always protect the cable from chafing by installing grommets.

Do not allow cables to rest in the bilge where prolonged immersion
in water, fuel, etc. could occur.

Always fit splash covers and lids on processors, computer units
and junctions boxes, where supplied.

4.1.3

Autopilot Drive Unit Cables

Cable Length

B&G Cable

Part No.

Copper

Area

Cable Gauge

Up to 8m/26ft

135-0A-128

4.0mm²

12 AWG

Up to 12m/40ft

Not available

6.0mm²

10 AWG

Up to 20m/65ft

Not available

10.0mm²

7 AWG

Table 4.1 All Rudder Drives - Heavy Duty Power Cables

Cable Length

B&G Cable Part

No.

Copper

Area

Cable Gauge

Up to 9m/30ft

135-0C-096

0.5mm²

22 AWG

Up to 15m/50ft

135-0B-096

0.5mm²

22 AWG

Table 4.2 Rams and Rotary Drives - Clutch/Valve Cables