Fig 4.7 continuous drive connections – B&G H2000 Pilot *DISCONTINUED* User Manual

Page 90

Advertising
background image

h2000 Autopilot User Manual
Part 4 - Installation Information

HB-0842-04

4-12

4.2.5

Continuous Drive Connections

These are general wiring instructions only, showing the
implementation of the ACP outputs to drive a continuous drive
pump solenoid valves. The continuous drive pump motor will also
require a heavy-duty supply, which is not provided. However,
suitable units can be obtained from your dealer. Clutch output is
used to control the motor supply.

Note:

The ram solenoid must be designed to operate at the

same voltage as the pump.

DRIVE

SUPPLY

DRIVE

SUPPLY

IN

OUT

-

+

-

1A

BR

BL

SLV

R

BL

SLV

BL

R

SLV

R

W

BR

G

V

BL

Y

BLK

SLV

R

G

SLV

BL

R

R

BL

SLV

G

W

Y

BR

R

BLK

SLV

R

G

BL

SLV

R

BL

SLV

R

BLK

G

W

BL

Y

SLV

BLK

G

R

SLV

CLUTCH

MOB

AL

ARM

PA
DDLE

G

Y

R

O

-S

T

A

B

IL

ISED

C

O

M

PASS

RUD

DER

J

O

YST

IC

K

HA

NDHE

LD

Rudder Reference Unit

RRF-ACP

Circuit Breaker

Heavy Duty

Power Supply

Bl

ack

Re

d

+

-

PORT

STBD

Continuous Drive

Pump Solenoid

Valves

Ram

Solenoid

Continuous

Running

Pump

Circuit Breaker*

Relay*

CR Pump

Supply

Bl

u

e

Brown

Clutch

Output

-

+

-

+

*Not supplied by B&G

Fig 4.7 Continuous Drive Connections

Advertising