TO R Q U E M O D U L E I N S T A L L A T I O N
Load Cell Installation
Version 2
Torque Module Installation and User Guide for Model 250i Dynamometers
1-9
3
Install the load cell.
3a
Verify the eyelets on the load cell are spaced the same as the bar removed
earlier.
Adjust the load cell spacing by loosening the lock nut and turning the eyelet.
Figure 1-8: Verify Load Cell Spacing
3b
Orient the load cell so the cable faces the dynamometer.
3c
Secure the load cell to the mounting bracket using the two bolts and nuts
removed earlier.
Figure 1-9: Install the Load Cell
distance must be
the same
eyelet
bar
lock nut
load cell cable
load cell