Torque Module Installation and User Guide for Model 250i Dynamometers

A P P E N D I X A
Torque Module Calibration

A-6

7

Install the calibration arm and weights using the bolt pattern at the end of the
calibration arm.
Note: If you do not have enough room to use the bolt pattern closest to the end
of the calibration arm, use the bolt pattern in the center of the arm. Refer to
Figure A-8 on page A-7.
7a

Secure the calibration arm to the eddy current brake using the handle to
tighten the bolt.

7b

Gently place the weights on the calibration arm.

The calibration weights are very heavy. The weights must be set on the arm
gently or you will damage the load cell.

Figure A-7: Install Calibration Arm and Weights Using the Bolt Pattern Closest to the End

weights

weight support

pin

secure arm to brake by

tightening the handle