Torque Module Installation and User Guide for Model 250i Dynamometers
C H A P T E R 2
Torque Cell Calibration
2-6
If you do not have enough room to use the bolt pattern closest to the end of the
calibration arm, use the bolt pattern in the center of the arm as shown in
Figure 2-6.
Figure 2-6: Install Calibration Arm and Weights Using the Bolt Pattern in the Center
weights
secure arm to brake by
tightening the handle
weight support
pin