Connecting the rpm pickup, Rpm pickup descriptions – Dynojet 424xLC2: Installation Guide User Manual

Page 132

Advertising
background image

C H A P T E R 6

Connecting the RPM Pickup

Above Ground Model 424x/424xLC

2

Automotive Dynamometer Installation Guide

6-6

CONNECTING THE RPM PICKUP

Your Dynojet dynamometer includes a primary wire inductive pickup and two
secondary wire inductive pickups. These small “clothespin like” inductive pickups are
used to sense RPM. An RPM pickup is required if you want to view torque graphs.
Generally you will use one secondary wire inductive pickup on a spark plug wire. The
primary wire inductive pickup senses RPM pulses from the coil. Although this pickup
location generally works better, it is harder to find the correct location to connect the
RPM pickup.

The optional Optical Sensor is useful on diesel powered vehicles, MSD ignitions, and
other high RFI ignition systems. For more detailed information on the Optical Sensor,
refer to the Optical RPM Sensor Installation Guide (P/N 98200044).

Inductive pickups are very fragile. The ferrite core can easily be damaged
and is not covered under warranty. Dropping, snapping, vibration, and
heat can all damage the ferrite core.

The DynoWare RT contains the electronics that sense the RPM pulses.

You will need the following parts:

RPM P

ICKUP

D

ESCRIPTIONS

part

description

part

description

inductive primary

pickup (2)

P/N 76950201

inductive secondary 

pickup (2)

P/N 76950203

RPM pickup

description

Secondaries (Non- wasted spark system)

Use one secondary pickup. Set the degrees between plug fires to

720° in Power Core.

Secondaries (Wasted spark ignition

system)

Use one secondary pickup. Set the degrees between plug fires to

360° in Power Core.

Primary pickup

Attach the primary wire pickup to the primary side of the coil. Set

the degrees between plug fires by taking 720/number of cylinders.

For example, the number of degrees between plug fires on a V-8

engine with a single coil is 720/8=90 degrees.

Optional Optical RPM Sensor

Attach the sensor wire to the RPM port on the main module. The

other end of the wire attaches to the Optical Sensor. Set the degrees

between plug fires to 360° in Power Core. Refer to the Optical RPM

Sensor Installation Guide (P/N 98200044).

Advertising
This manual is related to the following products: