9 eventlog, Error variable structure – Kontron AM4901 IPMI User Manual

Page 24

Advertising
background image

IPMI Firmware User Guide

AM5901/AM4901

Page 24

ID: 1035-8760, Rev. 3.0

3.9

Eventlog

The MCH provides the IPMI System Eventlog (SEL) with a non-volatile buffer for up to 1023
entries. In order to prevent a buffer overflow and resulting loss of event records, the buffer must
be periodically emptied. Access to the Eventlog buffer of the MCH can be effected best from
an AMC processor module over the IPMB-L bus using the free software tool “ipmitool”. A buffer
overflow is of no consequence for the MCH, but can, however, be of relevance to system man-
agement software. The events stored in the Eventlog are state changes of sensors implement-
ed in the MCH. Possible events are described later in this guide.

3.10

Error Variables, Error Indication, and Error Clearing

The MCH provides an error variable which can be read via the CLI command “showerror”. The
clearing of particular bits can be effected using the CLI command “clearerror”. Some errors are
self-clearing when the condition that caused them no longer exists. Self-clearing and clearing
per command are explicitly indicated in the following tables.
Table 4:

Error Variable Structure

BITS

OBJECT

FORMAT

DESCRIPTION

31

---

---

Reserved

30

eventProcessing

bool

1 = Error when storing an event in the event log. Possibly the

event log is full.

0 = No error

29

powerMissing

bool

1 = Not enough current deliverable by the power module or

more current for a slot required than allowed. Refer to 1)
CLI commands ‘currentopts’, 2) backplane FRU data
‘MicroTCA Carrier Power Policy record’ and ‘Car-
rier Activation and Power Management record’
and 3) OEM IPMI commands ‘Set Current Options
Parameters’, ‘Get Current Options Parameters’

0 = No error

28

fru3DataMissing

bool

1 = FRU data for FRU ID 3 (MCMC) not readable. Load the FRU

data and reset the MCH.

0 = No error

27

Fru2DataMissing

bool

1 = FRU data for FRU ID 2 or 253 (Backplane) is not readable.

Load the FRU data and reset the MCH.

0 = No error

26

Fru0DataMissing

bool

1 = FRU data for FRU ID 0 (CM) not readable. Load the FRU

data and reset the MCH.

0 = No error

25:23

shAddrDevice

device

State of the shelf address read device. Runtime errors can be
cleared.

22:20

tempCtrlDevice

device

State of the temperature control device. Please note: Does not
report temperature errors. Runtime errors can be cleared.

Advertising