ID: 1035-8760, Rev. 3.0

fan

<speed (hex)>

Set the fan speed level to 0…f (min…max). Please note that the
manual setting is only possible if the temperature control is
switched off

R

Display the real fan speed [rpm]

R

help

Print online help of all commands with parameter descriptions

UR

lan

print 1

Display all current LAN parameters for the management port

R

set 1 macaddr
<x:x:x:x:x:x>

Set the management port’s MAC address (x = hex)

R

set 1 ipaddr <x.x.x.x>

Set the management port’s IP address (x = dec)

R

set 1 netmask <x.x.x.x>

Set the management port’s subnet mask (x = dec)

R

set 1 vlan <x>

Set the vlan ID x (x = dec, 0 < x < 4095)

R

set 1 vlan off

Set the vlan support off

R

set 1 access on

Set the management port channel access mode to on

R

set 1 access off

Set the management port channel access mode to off

R

led

Access to Carrier Management LEDs

on|off

MCMC (on) or Switch (off) controls CMLEDs 1..13

R

set|clr <led#>

Set or clear a single LED (requires 'led on').
<led#>: 1 - d = LED number (hex)

R

all <mask>

Set or clear all LEDs (requires 'led on').
<mask>: 0 - 2ffe One bit per CMLED 1..13
0 All LEDs off
2ffe All LEDs on

R

login

<current password>

Log in using the current password to be able to use root (R)
commands. If no password was defined until now no login is
needed.

UR

logout

From now on no root (R) commands can be used if a password
is currently defined.

R

md

[<adr>]

Display memory contents.
<adr> in hex to define start of display; default is end of last dis-
play

UR

Table 6:

CLI Command List

Command

Parameters

Description

User

or

Root

Advertising