Kontron AM4901 IPMI User Manual
Page 32
IPMI Firmware User Guide
AM5901/AM4901
Page 32
ID: 1035-8760, Rev. 3.0
fan
<speed (hex)>
Set the fan speed level to 0…f (min…max). Please note that the
manual setting is only possible if the temperature control is
switched off
R
Display the real fan speed [rpm]
R
help
Print online help of all commands with parameter descriptions
UR
lan
print 1
Display all current LAN parameters for the management port
R
set 1 macaddr
<x:x:x:x:x:x>
Set the management port’s MAC address (x = hex)
R
set 1 ipaddr <x.x.x.x>
Set the management port’s IP address (x = dec)
R
set 1 netmask <x.x.x.x>
Set the management port’s subnet mask (x = dec)
R
set 1 vlan <x>
Set the vlan ID x (x = dec, 0 < x < 4095)
R
set 1 vlan off
Set the vlan support off
R
set 1 access on
Set the management port channel access mode to on
R
set 1 access off
Set the management port channel access mode to off
R
led
Access to Carrier Management LEDs
on|off
MCMC (on) or Switch (off) controls CMLEDs 1..13
R
set|clr <led#>
Set or clear a single LED (requires 'led on').
<led#>: 1 - d = LED number (hex)
R
all <mask>
Set or clear all LEDs (requires 'led on').
<mask>: 0 - 2ffe One bit per CMLED 1..13
0 All LEDs off
2ffe All LEDs on
R
login
<current password>
Log in using the current password to be able to use root (R)
commands. If no password was defined until now no login is
needed.
UR
logout
From now on no root (R) commands can be used if a password
is currently defined.
R
md
[<adr>]
Display memory contents.
<adr> in hex to define start of display; default is end of last dis-
play
UR
Table 6:
CLI Command List
Command
Parameters
Description
User
or
Root