Kontron AM4901 IPMI User Manual

Page 35

Advertising
background image

AM5901/AM4901

IPMI Firmware User Guide

ID: 1035-8760, Rev. 3.0

Page 35

tcp

<initialFanLevel>
<minFanLevel>
<coolingFanIncrease-
Timeout>
<coolingFanDecrease-
Timeout>
<fanLevelStepUp>
<fanLevelStepDown>
<normalStableTime>

Set temperature control parameters (hex)

R

Display the current temperature control parameters (hex).
Example:

Read temperature control parameters

(hex):

initialFanLevel = 08

minFanLevel = 03

coolingFanIncreaseTimeout = 3C

coolingFanDecreaseTimeout = 3C

fanLevelStepUp = 02

fanLevelStepDown = 01

normalStableTime = 0708

R

test

5

Test the watchdog. If the watchdog is configured after 10 sec-
onds a reset must be executed.

R

tipmi

<NetFn> <Lun> <Cmd>
[<Byte>*]

Send a raw IPMI command to the MCH’s MMC.
<NetFn> : Network function code
<Lun>

: Logical unit number

<Cmd>

: IPMI command

<Byte>

: Request data byte(s)

R

tipmb

<SA> <NetFn> <Lun>
<Cmd> [<Byte>*]

Send a raw IPMI command (using Send Message) to a
SlaveAddress on IPMB-L.
<SA>

: Slave Address

<NetFn> : Network function code
<Lun>

: Logical unit number

<Cmd>

: IPMI command

<Byte>

: Request data byte(s)

R

upon

Enable firmware update. Warning: This will cancel normal oper-
ation immediately!

R

Table 6:

CLI Command List

Command

Parameters

Description