3 set fan speed parameter, 4 get fan speed parameter, Set fan speed parameter – Kontron AM4901 IPMI User Manual

Page 66: Get fan speed parameter

Advertising
background image

IPMI Firmware User Guide

AM5901/AM4901

Page 66

ID: 1035-8760, Rev. 3.0

8.2.3

Set Fan Speed Parameter

This command writes the fan speed parameter to the related NV-Parameter, saves this to EE-
PROM, and forces the new fan speed. It works only if automatic temperature control is inactive.

8.2.4

Get Fan Speed Parameter

This command reads the current fan speed parameter.

COMMAND

LUN

NetFn

CMD

SetFansSpeedParameter

00h

OEM = 3Eh

24h

REQUEST DATA

Byte

Data Field

1

Kontron IANA LSB

2

Kontron IANA byte 2

3

Kontron IANA MSB

4

Fan speed level 0…0xf

RESPONSE DATA

Byte

Data Field

1

Completion Code

2

Kontron IANA LSB

3

Kontron IANA byte 2

4

Kontron IANA MSB

COMMAND

LUN

NetFn

CMD

GetFansSpeedParameter

00h

OEM = 3Eh

25h

REQUEST DATA

Byte

Data Field

1

Kontron IANA LSB

2

Kontron IANA byte 2

3

Kontron IANA MSB

RESPONSE DATA

Byte

Data Field

1

Completion Code

2

Kontron IANA LSB

3

Kontron IANA byte 2

4

Kontron IANA MSB

5

Fan speed level 0…0xf

Advertising
This manual is related to the following products: