5 set permanent power parameter, 6 get permanent power parameter, Set permanent power parameter – Kontron AM4901 IPMI User Manual

Page 67: Get permanent power parameter

Advertising
background image

AM5901/AM4901

IPMI Firmware User Guide

ID: 1035-8760, Rev. 3.0

Page 67

8.2.5

Set Permanent Power Parameter

This command writes the permanent power parameter to the related NV-Parameter and saves it.

8.2.6

Get Permanent Power Parameter

This command gets the permanent power parameter from the related NV-Parameter.

COMMAND

LUN

NetFn

CMD

SetPermPwrParameter

00h

OEM = 3Eh

26h

REQUEST DATA

Byte

Data Field

1

Kontron IANA LSB

2

Kontron IANA byte 2

3

Kontron IANA MSB

4:7

Permanent power parameter. LSB first.
Note: AMC Slot 1 = bit 5

RESPONSE DATA

Byte

Data Field

1

Completion Code

2

Kontron IANA LSB

3

Kontron IANA byte 2

4

Kontron IANA MSB

COMMAND

LUN

NetFn

CMD

GetPermPwrParameter

00h

OEM = 3Eh

27h

REQUEST DATA

Byte

Data Field

1

Kontron IANA LSB

2

Kontron IANA byte 2

3

Kontron IANA MSB

RESPONSE DATA

Byte

Data Field

1

Completion Code

2

Kontron IANA LSB

3

Kontron IANA byte 2

4

Kontron IANA MSB

5:8

Permanent power parameter. LSB first.
Note: AMC Slot 1 = bit 5

Advertising
This manual is related to the following products: