420 Plus Installation Manual - Configuration

15

3.0

Configuration

To configure the

420 Plus

indicator, the indicator must

be placed in setup mode. The setup switch is accessed

by removing the large fillister head screw on the

enclosure bottom. Switch position is changed by

inserting a screwdriver or similar tool into the access

hole and pressing the setup switch.
When the indicator is placed in setup mode, the word

CONFIG

is shown on the display. The CONFIG menu is

the first of ten main menus used to configure the

indicator. Detailed descriptions of these menus are

given in Section 3.2 on page 17. When configuration is

complete, return to the CONFIG menu and press the

(

ZERO

) key to exit setup mode, then replace the setup

switch access screw.

3.1

Configuration Methods

The

420 Plus

indicator can be configured by using the

front panel keys to navigate through a series of

configuration menus or by sending commands or

configuration data to the EDP port. Configuration

using the menus is described in Section 3.1.3 on

page 16.
Configuration using the EDP port can be accomplished

using either the EDP command set described in

Section 5.0 or the

Revolution

®

software.

3.1.1

Revolution Configuration

The

Revolution

configuration utility provides the

preferred method for configuring the

420 Plus

indicator.

Revolution

runs on a personal computer to

set configuration parameters for the indicator. When

Revolution

configuration is complete, configuration

data is downloaded to the indicator.

Figure 3-1. Sample Revolution Configuration Display

Revolution

supports both uploading and downloading

of indicator configuration data. This capability allows

configuration data to be retrieved from one indicator,

edited, then downloaded to another.
To use

Revolution

, do the following:

1. Install the

Revolution

module on an

IBM-compatible personal computer running
Windows

®

98 or later. Minimum system

requirements are 4MB of extended memory

and at least 5MB of available hard disk space.

2. With both indicator and PC powered off,

connect the PC serial port to the indicator EDP

port.

3. Power up the PC and the indicator. Use the

setup switch to place the indicator in setup

mode.

4. Start the

Revolution

program.

Figure 3-1 shows an example of one of the

Revolution

configuration displays.

Revolution

provides online help for each of its

configuration displays. Parameter descriptions

provided in this manual for front panel configuration

can also be used when configuring the indicator using

Revo lu t io n

: the interface is different, but the

parameters set are the same.

3.1.2

EDP Command Configuration

The EDP command set can be used to configure the

420 Plus

indicator using a personal computer, terminal,

or remote keyboard. Like

Revolution

, EDP command

configuration sends commands to the indicator EDP

port; unlike

Revolution

, EDP commands can be sent

using any external device capable of sending ASCII

characters over a serial connection.
EDP commands duplicate the functions available using

the indicator front panel and provide some functions

not otherwise available. EDP commands can be used to

simulate pressing front panel keys, to configure the

indicator, or to dump lists of parameter settings. See

Section 5.0 on page 33 for more information about

using the EDP command set.