3 continuous output (stream) format – Rice Lake 420 Plus HMI Digital Weight Indicator Installation Manual User Manual

Page 48

Advertising
background image

44

420 Plus Installation Manual

7.3

Continuous Output (Stream) Format

Figure 7-1 shows the continuous output format sent to the

420 Plus

EDP or printer port when the STREAM

parameter (SERIAL menu) is set to either EDP or PRN.

<STX> <POL> <wwwwwww> <UNIT> <G/N> <S> <TERM>

ASCII 02
(decimal)

Weight data: 7 digits, right-justified, with
decimal point, l eading zer o s upr e ssion.
Overload = ^^^^^^^
Underrange = ] ] ] ] ] ] ]
Display overflow = OVERFL

L = pounds
K = kilogram
T = ton
G = grams
O = ounces
<space> = none

G = Gross
N = Net

Status:
< space > = valid
I = Invalid
M = Motion
O = Over/under range

Polarity:

< space > = Positive

<–> = Negative

<^> = Overload

<]> = Underrange

<CR> <LF>

or <CR>

ASCII 13, 10

(decimal)

Figure 7-1. Continuous Output Data Format