420 Plus Installation Manual - Introduction

3

1.2

Front Panel Keypad

Figure 1-1 shows the

420 Plus

LED annunciators,

keypad, and normal mode key functions.

The symbols shown above the keys (representing up,

down, enter, left, right) describe the key functions

assigned in setup mode. In setup mode, the keys are

used to navigate through menus, select digits within

numeric values, and increment/decrement values. See

Section 3.1.3 on page 16 for information about using

the front panel keys in setup mode.

lb

kg

Count

Gross

Net

DISPLAY

TARE

SETPOINT

TIME/DATE

POWER

I/O

2

3

4

5

7

8

9

0

6

CLR

ZERO GROSS

NET

TARE

ENTER

MODE SAMPLE

UNITS PRINT

Figure 1-1. 420 Plus Front Panel, Showing LED Annunciators and Normal Mode Key Functions

1.3

LED Annunciators

The

4 2 0 Pl u s

display uses a set of eight LED

annunciators to provide additional information about

the value being displayed:

Gross

and

Net

annunciators are lit to show

whether the displayed weight is a gross or net

weight.

Center of zero (

): Gross weight is within

0.25 graduations of zero. This annunciator

lights when the scale is zeroed.

Standstill (

): Scale is at standstill or

within the specified motion band. Some

operations, including tare functions and

printing, can only be done when the standstill

symbol is shown.

lb

and

kg

annunciators indicate the units

a s s o c i a t e d w i t h t h e d i s p l a y e d v a l u e :

lb=pounds, kg=kilograms.

The displayed units can also be set to short

tons (tn), metric tons (t), ounces (oz), grams

(g), or NONE (no units information displayed).

The

lb

and

kg

LEDs function as primary and

secondary units annunciators for some

combinations of primary and secondary units.

If neither primary nor secondary units are lb or

kg the

lb

annunciator is lit for primary units,

kg

for secondary units.

The

Count

annunciator is lit to show that the

indicator is in piece count mode.

The Tare Acquired (

) lights to show that a

tare value was entered.