SETPNT Menu

Parameter

Choices

Description

Level 2 submenus

SETPT1
SETPT2

ENABLE
KIND
VALUE
TRIP
BNDVAL

Specify settings for setpoint enable, kind, weight value, trip, and band value used by the
setpoint

Level 3 submenus

ENABLE

OFF
ON

Turn setpoint ON or OFF.

KIND

GROSS
NET

Specifies the setpoint kind and determines whether function is based on GROSS or NET
weight.

GROSS or NET setpoint kinds can be used.

VALUE

number

Display and edit the setpoint value

TRIP

HIGHER
LOWER
INBAND
OUTBND

Trips the setpoint when the weight is higher or lower than the setpoint value, or is within or
outside of the band value. LOWER means the output is active until you reach weight. If trip is
HIGHER, the output is active when the setpoint is met or exceeded. INBAND means the
output is active if the weight is within the band value. If trip is OUTBND, the output is active
when the weight is outside of the band value.

BNDVAL

number

The band value for either INBAND or OUTBND trip setpoints. BNDVAL is ignored unless trip is
set to INBAND or OUTBND.

HYSTER

number

Specifies a band around the setpoint value that must be exceeded before the setpoint, once
off, can trip on.

ACCESS

OFF
ON

Front panel access to setpoints. Specify OFF if setpoints will not be used. ON enables
operator to turn setpoints on/off, change value, or change BANDVAL via front panel entry
during weigh mode.

26

420 Plus Installation Manual

Table 3-7. Setpoint Menu Parameters

Advertising