Table 5-7. PROGRM EDP Commands

Command

Description

Values

PWRUPMD

Power up mode

GO, DELAY

CNTMOD

Counting Mode

ENABLE, DSABLE, SPLSIZ

REGULAT

Regulatory compliance

NTEP, OIML, CANADA, NONE

SPLSIZ

Sample size

10, 20, 50, 100, 5, PCWGT

CONSNUM

Consecutive number

0–999 999

CONSTUP

Consecutive number start-up value

0–999 999

DATEFMT

Date format

MMDDYY, DDMMYY, YYMMDD, YYDDMM

DATESEP

Date separator

SLASH, DASH, SEMI

TIMEFMT

Time format

12HOUR, 24HOUR

TIMESEP

Time separator

COLON, COMMA

ACCUM

Accumulator

ON/OFF

ACCUM. RTZGRADS

Return to zero trigger

0 - 10,000 GRADS

Table 5-8. PFORMT EDP Commands

Command

Description

Values

GFMT

Gross demand print format
string

See Section 6.0 on page 39 for detailed information

NFMT

Net demand print format string

CFMT

Count demand print format
string

Table 5-9. SETPNTS EDP Commands

Command

Description

Values

SP1

SP2

SP1.ENABLE

SP2.ENABLE

Setpoint enable

OFF, ON

SP1.KIND

SP2.KIND

Setpoint kind

GROSS, NET

SP1.VALUE

SP2.VALUE

Setpoint value

number

SP1.TRIP

SP2.TRIP

Trip

Higher, Lower, Inband, Outbnd

SP1.BNDVAL

SP2.BNDVAL

Band value

number

SP1.HYSTER

SP2.HYSTER

Hysteresis

number

SP1.ACCESS

SP2.ACCESS

Setpoint access

OFF, ON

Table 5-10. DIG IN EDP Commands

Command

Description

Values

DIGIN1
DIGIN2

Digital input function

OFF, ZERO, TARE, NT/GRS, UNITS, DSPTAR, PRINT, CLRCN,
KBDLOC, HOLD, CLRTAR, ACCUM, CLRACC, NEWID