Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 1.0 User Manual

Page 32

Advertising
background image

26

Counterpart User Manual

RECALL

ON
OFF

ON allows the Tare, Zero, and Units values to be maintained across a power cycle. Over/
Under/Target/ID values are also maintained.

OFF clears the values on a power cycle. Zero is reset to calibrated zero and Units are reset to
Primary. Over/Under/Target/ID values are reset as well.


DISPLAY

CONTRAST
BRIGHT
IMAGE

Adjusts Counterpart display viewing. Key in a value
BRIGHT - Key in a value
IMAGE - enter negative or positive

KEYBEEP

OFF
ON

Select ON to alert the user every time a key is pressed.

Level 4 submenus - under the Level 3 Count Feature

NEGCOUNT

ON
OFF

Sets whether negative weighing mode is off or on.

SAMPLQTY

10
25
50
100

Is the default value for sample quantity.

INSFSMPLE

0.1
0.2
0.0

A minimum sample size is required based on the platform capacity and product weight.

LOTUPDT

OFF
ON

Updates the lot number from the front panel softkey.1 It does not override the stored value.

SCLCHG

REZERO
CHKSTABLE
XFRTARE
XFRUTWT

Scale change. These are actions taken when changing from one scale to another.

NEWITEM

OFF
ON

New item. This prompts to add an ID to memory from the front panel.

DISPACC

OFF
ON

Display accuracy

UTWTUPDT

OFF
ON

Enables or disables the updating of the loaded ID with a new unit weight value.

OFF - Parts can be sampled (generating a new unit weight) or a unit weight can be keyed or
scanned but the new unit weight is not saved into the stored copy of the currently loaded ID
record.

ON - If on, the unit weight will update the stored value whether at zero or actual value.

UTWTBASE

1000
1

Unit weight base. 1=APW (Average Piece Weight), 1000=Piece weight per thousand.

FEATUR Menu

Parameter

Choices

Description

Table 3-7. FEATUR Submenu Parameters (Continued)

Advertising