8 normal mode commands, 9 unique commands, Normal mode commands – Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 1.0 User Manual

Page 63: Unique commands

Advertising
background image

Counterpart User Manual - Serial Commands

57

6.1.8

Normal Mode Commands

The normal mode print commands (see Table 6-12) transmit data to the serial port on demand in either setup or
normal mode.

6.1.9

Unique Commands

Command

Description

Values

CONSNUM#n

Set consecutive number

0–9 999 999

UID#n

Set unit ID

nnnnnnn

SD#n

Set date

MMDDYY, DDMMYY, YYMMDD, or YYDDMM. Enter
six-digit date using the year-month-day order specified
for the DATEFMT parameter, using only the last two
digits of the year.

ST#n

Set time

hhmm (enter using 24-hour format)

SX#n

Start serial port streaming

OK or ??
An EX command sent while in menu mode does not
take effect until the indicator is returned to normal
mode.
The EDP.Stream must be set to LFT or INDUST for this
command to work.

EX#n

Stop serial port streaming

XG#n

Transmit gross weight in displayed units

nnnnnn UU

where nnnnnn is the weight value, UU is the units.
NOTE: You can also send XGP, XGS, XGT, XTP, etc. to
specify primary, secondary or tertiary (P.S.T.).

XN#n

Transmit net weight in displayed units

XT#n

Transmit tare weight in displayed units

XA#n

Transmit accumulator value

RS

Reset system

Soft reset. Used to reset the indicator without resetting
the configuration to the factory defaults.

Table 6-12. Normal Mode Serial Commands

Command

Description

DUMPID.INDEX=n

To dump an ID by register

DUMPID.CODE=n

To dump an ID by code

Table 6-13. Unique Commands