Counterpart User Manual
The 500-character limit of each print format string includes the output field length of the print formatting commands,
not the command length. For example, if the indicator is configured to show a decimal point, the <G> command
generates an output field of 13 characters: the 10-character weight value (including decimal point), one space, and
a two-digit units identifier.
Gross, net, and tare weights are 8 digits in length, including sign and decimal point, followed by a
space and a one- to five-digit units identifier. Total field length with units identifier is 10-14 characters.
Depending on what units are configured, the units identifier will be lb, oz, g, or kg.
Gross, net, tare, and accumulator weights can be printed in any configured weight units by adding the
following modifiers to the gross, net, tare, and accumulator weight commands: /P (primary units), /D
(displayed units), /S (secondary units), /T (tertiary units). If not specified, the current displayed units (/
D) is assumed. Example: To format a ticket to show net weight in secondary units, use the following
command: <N/S>.
UNIT ID and consecutive number (CN) fields are 1–6 characters in length, as required.
* If nn is not specified, 1 is assumed. Value must be in the range 1–99.
** After receiving an SU command, the indicator sends unformatted data until the next SU command
is received. Unformatted data omits decimal points, leading and trailing characters.
Format
Default Format String
Used When
NFMT
N<NL>A30,75,0,4,1,1,N,"Gross:
<G>"<NL>B30,115,0,3,2,4,101,B,"<G>"<NL>A30,300,0,4,1,1,N,
"Tare: <T>"<NL>B30,340,0,3,2,4,101,B,"<T>"<NL>A30,525,0,4,1,1,N,
"Net: <N>"<NL>B30,565,0,3,2,4,101,B,"<N>"<NL>A30,806,0,3,1,1,N,"<TD>"<NL>
P1<NL>
Normal mode, tare in
system
PALFMT
N<NL>A416,25,1,4,1,1,N,"ID CODE:
<IDC>"<NL>B378,25,1,3,2,4,51,N,"3<IDC>"<NL>A296,28,1,4,1,1,N,"Total QTY:
<C>"<NL>B264,22,1,3,2,4,51,N,"<C>"<NL>
A179,25,1,4,1,1,N,"Part Name: <IDD>"<NL>A126,25,1,4,1,1,N,"Part Number:
<IDP>"<NL>A73,25,1,4,1,1,N,"Lot Number: <IDLT>"<NL>P1<NL>
Print mode
CFMT
N<NL>B371,20,1,3,2,4,51,N,"3<IDC>"<NL>A410,20,1,4,1,1,N,"ID. CODE:
<IDC>"<NL>A302,22,1,4,1,1,N,"QTY:
<C>"<NL>B264,20,1,3,2,4,51,N,"<C>"<NL>A280,400,1,4,1,1,N,"GROSS
<G>"<NL>
A225,400,1,4,1,1,N,"TARE
<T>"<NL>B189,355,1,3,2,4,51,N,"4<T>"<NL>A120,400,1,4,1,1,N,"NET
<N>"<NL>A195,24,1,4,1,1,N,"WT/K OR U
W"<NL>B124,20,1,3,2,4,51,N,"1<IDW>"<NL>
A47,16,1,4,1,1,N,"<TD>"<NL>A160,24,1,4,1,1,N,"<IDW>"<NL>P1<NL>
Count mode
GFMT
N<NL>A410,32,1,5,2,1,N,"<TOTAL
QUANTITY>"<NL>A57,532,1,3,1,1,N,"<TD>"<NL>A309,39,1,5,2,1,N,"<TV>"<NL>B
195,32,1,3,2,4,101,N,"<TV>"<NL>
A61,32,1,5,1,1,N,"BOX COUNT: <TC>"<NL>P1<NL>
Normal mode, no tare in
system
TOTAL
N<NL>A410,32,1,5,2,1,N,"<TOTAL
QUANTITY>"<NL>A57,532,1,3,1,1,N,"<TD>"<NL>A309,39,1,5,2,1,N,"<TV>"<NL>B
195,32,1,3,2,4,101,N,"<TV>"<NL>
A61,32,1,5,1,1,N,"BOX COUNT: <TC>"<NL>P1<NL>
Totalization mode
ACCFMT
ACCUM<A><NL><DA> <TI><NL>
Accumulator enabled
and displayed
Table 7-2. Default Print Formats
Command
Description
Supported Ticket
Formats
Table 7-1. Print Format Commands
Note