Counterpart User Manual - For More Information

69

<M[G | N | T]>

STR.GROSS
STR.NET
STR.TARE

Mode. Specifies gross, net, or tare weight for the current or
specified weight on the source scale.

<S>

STR.MOTION
STR.RANGE
STR.OK
STR.INVALID

Status for the source scale. Default values and meanings for each
status:
STR.MOTIONMIn motion
STR.RANGEOOut of range
STR.OK<space>OK
STR.INVALIDIInvalid

<CW>

Status of over/under/accept. O=Over, U=Under, A=Accept.

<B [–]n,…>

See descriptions below

Bit fields. Comma-separated sequence of bit field specifiers. Must
be exactly 8 bits. Minus sign ([–]) inverts the bit.

B0

Always 0

B1

Always 1

B2

Configuration

=1 if even parity

B3

Dynamic

=1 if MODE=NET

B4

Dynamic

=1 if COZ

B5

Dynamic

=1 if standstill

B6

Dynamic

=1 if gross negative

B7

Dynamic

=1 if out of range

B8

Dynamic

=1 if secondary/tertiary

B9

Dynamic

=1 if tare in system

B10

Dynamic

=1 if tare is keyed

B11

Dynamic

=00 if MODE=GROSS
=01 if MODE=NET
=10 if MODE=TARE
=11 (not used)

B12

Dynamic

=00 if UNITS=PRIMARY
=01 if UNITS=SECONDARY
=10 if UNITS=TERTIARY
=11 (not used)

B13

Configuration

=00 (not used)
=01 if current DSPDIV=1
=10 if current DSPDIV=2
=11 if current DSPDIV=5

B14

Configuration

=00 (not used)
=01 if primary DSPDIV=1
=10 if primary DSPDIV=2
=11 if primary DSPDIV=5

B15

Configuration

=00 (not used)
=01 if secondary DSPDIV=1
=10 if secondary DSPDIV=2
=11 if secondary DSPDIV=5

B16

Configuration

=00 (not used)
=01 if tertiary DSPDIV=1
=10 if tertiary DSPDIV=2
=11 if tertiary DSPDIV=5

Format Identifier

Defined By

Description

Table 9-3. Custom Stream Formatting