Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 1.0 User Manual

Page 62

Advertising
background image

56

Counterpart User Manual

REG.BASE

Zero base for overload calculation

CALIB, SCALE

REG.PRTMOT

Allow print while in motion

NO, YES

REG.PRINTPT

Add PT to keyed tare print

NO, YES

REG.SNPSHOT

Display or Scale weight source

DISPLAY, SCALE

SD

Set date

MMDDYY, DDMMYY, YYMMDD, or YYDDMM. Enter six-digit
date using the year-month-day order specified for the
DATEFMT parameter, using only the last two digits of the year.

ST

Set time

hhmm (enter using 24-hour format)

TIMEFMT

Time format

12HOUR, 24HOUR

TIMESEP

Time separator

COLON, COMMA

Command

Description

Values

GFMT.FMT

Gross demand print format string

See Section 7.0 on page 58 for information about demand print
format strings.

NFMT.FMT

Net demand print format string

ACC.FMT

Accumulator print format string

CFMT.FMT

Count format

TOTAL.FMT

Total Format

HDRFMT1

Header 1 Format

PALFMT.FMT

Pallet Format

HDRFMT2

Header 2 Format

Table 6-9. PFORMT Serial Commands

Command

Description

Values

DIO#b

Digital input function

OFF, ZERO, NT/GRS, TARE, UNITS, PRINT,
ACCUM, TIMDATE, ESC, CLEAR, DSPTAR,
IDKEY, KEY0–KEY9, KEYDP, ENTER, NAVUP,
NAVDN, NAVLFT, NAVRGT, KBDLOC, HOLD,
CLRCN, GROSS, NET, PRIM, SEC, CLRTAR,
CLRACC, TRIGGER

DIO#b

Digital output function

OVER, UNDER, ACCEPT, ZEROBD

Digital inputs and outputs are specified by bit number

Table 6-10. DIG I/O Serial Commands

Command

Description

Value

GFMT.PORT

Set the port for each of these commands

2

NFMT.PORT

ACC.PORT

CFMT.PORT

TOTAL.PORT

PALFMT.PORT

Table 6-11. Select Port Serial Commands

Command

Description

Values

Table 6-8. FEATURE Serial Commands (Continued)

Advertising