Scale Installation
23
When connections are complete, reinstall load cell connector on the A/D card and use two cable ties to secure the
load cell cable to the inside of the enclosure.
Table 2-2. A/D Card Pin Assignments
A/D Card
Connector Pin
Function
1
+SIG
2
–SIG
3
+SENSE
4
–SENSE
5
+EXC
6
–EXC
•
For six-wire load cell connections to connector J1, remove
jumpers JP1 and JP2.
•
For six-wire load cell connections to connector J2 (dual A/
D cards), remove jumpers JP3 and JP4.