Scale Installation

23

When connections are complete, reinstall load cell connector on the A/D card and use two cable ties to secure the

load cell cable to the inside of the enclosure.

Table 2-2. A/D Card Pin Assignments

A/D Card

Connector Pin

Function

1

+SIG

2

–SIG

3

+SENSE

4

–SENSE

5

+EXC

6

–EXC

For six-wire load cell connections to connector J1, remove

jumpers JP1 and JP2.

For six-wire load cell connections to connector J2 (dual A/

D cards), remove jumpers JP3 and JP4.