Rice Lake TradeRoute HL Series - Installation and Service Manual (Legal-for-Trade) User Manual
Page 33
920i® Electronic Weigh Center
29
The results in Table 3-3, show that load cells one and three must be adjusted down to read 4990 lb (1996 kg in the
metric example). First, the potentiometer for load cell one is turned to bring the reading down (step 6).
Table 3-4. Second Loading
English Units (lb)
Load Cell
Metric Units (kg)
920iReading
920i Reading
Start
Loaded
Unloaded
Start
Loaded
Unloaded
0
4990
0
1
0
1996
0
2
3
Next, the potentiometer for load cell three is turned to bring its reading down to 4985 lb (1994 kg in the metric
example) and check for a zero shift.
Table 3-5. Third Loading
English Units (lb)
Load Cell
Metric Units (kg)
920i Reading
920i Reading
Start
Loaded
Unloaded
Start
Loaded
Unloaded
1
2
0
4985
-5
3
0
1994
-2
The unloaded reading is found to be –5 lb (-2 kg), indicating a zero shift. The scale must therefore be rezeroed, and
load cell three checked again.
Table 3-6. Fourth Loading
English Units (lb)
Load Cell
Metric Units (kg)
920i Reading
920i Reading
Start
Loaded
Unloaded
Start
Loaded
Unloaded
0
4990
0
1
0
1996
0
0
4990
0
2
0
1996
0
0
4990
0
3
0
1996
0
The load cells are now balanced within the tolerance of one graduation.