Rice Lake TradeRoute HL Series - Installation and Service Manual (Legal-for-Trade) User Manual

Page 33

Advertising
background image

920i® Electronic Weigh Center

29

The results in Table 3-3, show that load cells one and three must be adjusted down to read 4990 lb (1996 kg in the

metric example). First, the potentiometer for load cell one is turned to bring the reading down (step 6).

Table 3-4. Second Loading

English Units (lb)

Load Cell

Metric Units (kg)

920iReading

920i Reading

Start

Loaded

Unloaded

Start

Loaded

Unloaded

0

4990

0

1

0

1996

0

2

3

Next, the potentiometer for load cell three is turned to bring its reading down to 4985 lb (1994 kg in the metric

example) and check for a zero shift.

Table 3-5. Third Loading

English Units (lb)

Load Cell

Metric Units (kg)

920i Reading

920i Reading

Start

Loaded

Unloaded

Start

Loaded

Unloaded

1

2

0

4985

-5

3

0

1994

-2

The unloaded reading is found to be –5 lb (-2 kg), indicating a zero shift. The scale must therefore be rezeroed, and

load cell three checked again.

Table 3-6. Fourth Loading

English Units (lb)

Load Cell

Metric Units (kg)

920i Reading

920i Reading

Start

Loaded

Unloaded

Start

Loaded

Unloaded

0

4990

0

1

0

1996

0

0

4990

0

2

0

1996

0

0

4990

0

3

0

1996

0

The load cells are now balanced within the tolerance of one graduation.

Advertising