E located on the junction box (see figure 3-5, Trade, Figure 3-5. trim potentiometers – Rice Lake TradeRoute HL Series - Installation and Service Manual (Legal-for-Trade) User Manual

Page 32: Example: ob30l-f3 system, Table 3-3. first loading

Advertising
background image

28

Trade

Route Installation Manual

5. Repeat step four for the other load cells with the same procedure (remembering to press the zero key to

obtain a good center of zero). All the readings should be within approximately 1 percent of each other. If

the readings are significantly farther apart, you may not be able to balance your system. Contact Rice Lake

Weighing Systems for technical assistance.

6. Pick the lowest reading and adjust the other load cells down to this value with the trimmers inside the

j-box.

7. With no weight on the scale, zero the indicator. Then turn all four potentiometers (shown in Figure 3-5) to

increase the reading until a clicking sound is heard from each potentiometer. This ensures the maximum

signal from each load cell.

JP4

JP2

PT4

PT3

JP3

PT1

EXP

PT2

JP1

1

CELL4

1

CELL1

1

CELL3

1

CELL2

IND

-EX

-SI

SHD

+SI

+EX

M

R

N

I

-SI

S2 C

I

A

G

+EX

+SI

-SI

SHD

-EX

I

S

G

A
L

T

+SI

M

S

I

N

L

T

R

+EX

-EX

-SI

SHD

+SI

+EX

+SI

-EX

-SI

SHD

-EX

SHD

+SE

-SE

+EX

Potentiometers

Jumper Locations

JP1 and JP2

Shaded

Jumper Locations

JP3 and JP4

Shaded

Potentiometers

Figure 3-5. Trim Potentiometers

With all potentiometers at full signal, place the test weight over one corner and record the indicated weight.

Repeat the process for each of the other three corners. The load cell with the lowest corner reading will be

used as a reference point and will not be trimmed.

8. Test the final balance by loading each load cell again and recording the 920i readings. The load cells must

read within one graduation of each other for an acceptable final balance. However, it is more desirable that

there be no difference in the readings (zero balance error).

9. The system can now be calibrated.

EXAMPLE: OB30L-F3 System

Balancing Weights
English = 5000 lb

Metric = 2000 kg

Graduations
English = 5 lb

Metric = 2 kg

Table 3-3. First Loading

English Units (lb)

Load Cell

Metric Units (kg)

920i Reading

920i Reading

Start

Loaded

Unloaded

Start

Loaded

Unloaded

0

4995

0

1

0

1998

0

0

4990

0

2

0

1996

0

0

5005

0

3

0

2002

0

Advertising