4 calibration – Rice Lake TradeRoute HL Series - Installation and Service Manual (Legal-for-Trade) User Manual

Page 34

Advertising
background image

30

Trade

Route Installation Manual

3.4

Calibration

The CALIBR submenu (under the SCALES menu, see Figure 3-6) is used to calibrate the 920i. The zero, span, and

linear calibration point displays provide a set of softkeys used specifically for calibration procedures:

+/–

Toggles to allow entry of negative or positive values.

Last Zero

Recalls the last established zero value to allow calibration without removing tests weights or product

from scale.

Calibrate

Performs calibration for the selected point.

Temp Zero

Temporarily zeroes the displayed weight of a non-empty scale. After span calibration, the difference

between the temp zero and the previously calibrated zero value is used as an offset.

Millivolts

(or

Counts

)

Toggles between display of captured A/D counts and captured millivolts values; allows entry of

calibration values in mV or counts.

07/14/2006

01:57PM

Calibrate

WZERO

WVAL

REZERO

1291

Deadload Calibration

+/-

Millivolts

Zero Count =>

Last Zero

Temp Zero

CALIBR

SCALE1

SCALES

Figure 3-6. WZERO Calibration Display

To calibrate the indicator using the front panel:

1. Place the indicator in setup mode (display reads

Scale Configuration

) and remove all weight from the scale

platform. If your test weights require hooks or chains, place the hooks or chains on the scale for zero

calibration.

2. With the

SCALES

menu highlighted, press

and select the scale to be calibrated.

3. Press

again (

GRADS

parameter highlighted).

4. Press left to highlight the

CALIBR

submenu.

5. Press

to go to zero calibration (

WZERO

). See Figure 3-6.

6. Ensure scale is empty and press

again to show the current WZERO value.

7. Press the

Calibrate

softkey to calibrate zero. When complete, the new A/D count for the zero calibration is

displayed.

8. Press

to save the zero calibration value and go to the next prompt (

WVAL

).

9. With

WVAL

displayed, press

to show the stored calibration weight value.

Advertising