4.7.3. Logging

Log messages generated by the communications module

can be captured for review. Enabling the “DEBUG”

option may degrade the communications module

’s performance. It is recommended to not use this option

unless required.

Login → Maintenance → Logging

Figure 25 Logging

To configure logging over the network:

1.

Select the Network option. This option enables Logging Server fields.

2.

Enter the Logging Server IP Address and the Logging Server Port.

3.

Select the log levels for different modules from the drop-down menu.

4.

Click Apply to save the settings.

Note To disable logging, select Nowhere (Disable)

Note To download and save the log file on the computer, click the Download link.

Note A maximum of 500 KB of logging data can be collected. On exceeding this limit, the older 250 KB of
logging data are purged from the log file.