WEBS-CM-2, WEBS-PA-1 and WEBS-PA-2

Configuration and Operation Manual

Page 29 of 53

Copyright 2012 Talk-A-Phone Co.

• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected]• www.talkaphone.com.

All prices and specifications are subject to change without notice. Talk-A-Phone, Scream Alert, WEBS and WEBS Contact are registered trademarks of Talk-A-Phone Co. All rights reserved.

5. Operations

The communications module takes approximately one minute to boot. While the first and second LEDs are
flash, the unit is still booting (Refer to Figure 1 Front View). After all LEDs clear, wait for an additional twenty
seconds before initiating a call.

The communications module needs to be programmed in accordance with the instructions provided in
Chapter 4 (Refer to 4 Using the Web GUI).

5.1. Activating/Deactivating Auxiliary Outputs

To provide additional visible or audible alerts upon an event, the communications module is equipped with 3
Auxiliary Outputs. The Auxiliary Outputs can be used to connect devices such as a siren, a strobe light, a PTZ
camera, etc. These devices can then be activated and deactivated locally or remotely (Refer to 4.6.6 Auxiliary
Outputs).

5.2. Paging Operation

The communications module can receive one-way paging messages from the WEBS Contact® server either
on the line level output or on the built-in hands-free speaker. The communications module must be registered
with the WEBS Contact® server in order to receive incoming pages.

5.3. Rebooting the Communications Module

The communications module can be rebooted using the Reset button on the communications module.
Pressing the Reset button once will reboot the communications module. The communications module can
also be rebooted via the Web GUI (Refer to 4.8 Reboot).

5.4. Factory Default Settings

The communications module can be reset to factory settings using the Reset button. Press and hold the
Reset button for 10 seconds. The communications module will reboot with factory default settings.

Note: All data including IP address and username/password will be reset to factory defaults.