TimerRinger = 5

+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++ Field name : TimerHangup
++ Description : Hangup Timer
++ Valid values : 0.5 - 3.0 seconds, in increment of 0.1 second.
++ Default value is 0.5 secs
++ Note : None
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

TimerHangup = 0.500000

+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++ Field name : TimerInterDigitLocal
++ Description : Local Inter digit timer, used during dialing numbers.
++ Valid values : 5 - 20 seconds, in increment of 1 sec
++ Default value is 5 secs
++ Note : None
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

TimerInterDigitLocal = 5

+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++ Field name : TimerInterDigitRemote
++ Description : Remote Inter digit timer, used during Remote DTMF
++ operations
++ Valid values : 5 - 20 secs, in increment of 1 sec
++ Default value is 5 secs
++ Note : None
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

TimerInterDigitRemote = 5

+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++ Field name : CallConversation
++ Description : Used for limiting Call Conversation time.
++ Valid values : CallConversation = 0 , Calls lasts indefinite
++ CallConversation = 1 Calls lasts for definite time
++
++ Field name : TimerCallConversation
++ Description : Call Conversation time, call only lasts for this time,
++ applicable when CallConversation = 1
++ Valid values : 1 - 360 minutes in increments of 1 minute.
++ Default value is 12 minutes
++ Note : None
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

CallConversation = 1
TimerCallConversation = 12

+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++ Field name : RingBackBusy
++ Description : Enable/Disable Ringback Busy Timer.