Beckett 7600 AquaSmart Boiler Control User Manual

Page 14

Advertising
background image

14

Figure 13 - 7600A/B multi-zone connections

with or without a tankless coil

Water Flow:

Control Wiring (Option 1): Circulator-On and -Off Delays on Zone 1 ONLY

1. Set “DHWP OFF” (default, see programming section for instructions)
2. Set “C1 on TT” (default, see programming section for instructions)
3. Circulator-on and -off delays will only affect zone 1

CONTINUED ON NEXT PAGE ►

L2 L1 C1 C2 ZC ZR B1 B2

TR

TW

SK10020

6

5

4

3

2/N

1/H

T

T

ZONE

RELAY

ZONE

2

LOW VOLTAGE

THERMOSTAT

NEUTRAL

HOT

120 VAC

BLACK

WHITE

ZONE

1

LOW VOLTAGE

THERMOSTAT

P1

CIRCULATOR

120 VAC

P2

WHITE

RED

7600A:

120 VAC BURNER OR

GAS IGNITION SYSTEM

7600B:

24 VAC GAS

IGNITION SYSTEM

FIELD/MFR.

SUPPLIED

SERVICE

SWITCH

CIRCULATOR

120 VAC

6

5

4

3

2/N

1/H

T

T

ZONE

RELAY

ZONE

3*

LOW VOLTAGE

THERMOSTAT

P3*

CIRCULATOR

120 VAC

SK10031

P1

COLD

WATER

INLET

EXPANSION

TANK

HEATING

ZONE

1

AIR

SEPARATOR

AIR

VENT

HEATING

ZONE

2

P2

P3*

HEATING

ZONE

3*

* Additional zones can be added by duplicating

the plumbing and wiring of zone 3.