C. changing the circulator settings – Beckett 7600 AquaSmart Boiler Control User Manual

Page 28

Advertising
background image

28

3. Press the

“ENTER (RESET)”

key. The following

screen will be displayed:

1 ON> 2:15

OFF> 30:05 140F

A

B

C

D

4. To navigate the history menu, press

“▲”

or

“▼”

key

to view additional data and cycles.

5. Press the

“▼”

key to view the other data screen for

the most recent cycle. The following screen will be

displayed:

1 START> LL
END> SENSOR ERR

A

E

F

6. Press

CANCEL (BACK)”

to exit.

Key (for steps B3 & B5):

A = Current cycle data being displayed (1 being the most recent cycle)
B = Burner on time in minutes:seconds
C = Burner off time in minutes:seconds
D = Average water temperature over burner off-on cycle.
E = Cycle start reason:

LL = burner turned on to maintain low limit.

TT = burner turned on to satisfy a thermostat call for heat.

ZR = burner turned on to satisfy a ZR call for heat.

F = Cycle end reason:

CFH = the call for heat (from T-T or ZR) was satisfied

HL = the boiler water temperature reached the high operating limit.

LL = the boiler water temperature reached the low limit plus low
differential.

Lockout reasons (see Lockout Troubleshooting section for more
details): SENSOR ERR, SELF-CHECK, CANCEL

C. Changing the Circulator Settings

The circulator-off delay keeps the C1 output energized

for the set time after a call for heat ends. This helps to

increase the efficiency of the system by transferring

more heat into the home instead of letting it sit in the

boiler.

The circulator-on delay holds the C1 output off for the

set time at the start of a call for heat. This helps the

boiler to heat up more quickly and spend less time in the

condensing range (if applicable).

Both circulator delays are selectable from 0 to 4 minutes

and 15 seconds.

1. In any mode other than an OPTION sub-menu,

press the

OPTION”

key. The following screen will

be displayed:

HEAT MANAGR MENU

ENTER TO VIEW

2. Press the

“▲”

and

“▼”

keys until the following

screen is displayed:

CIRCULATOR MENU

ENTER TO VIEW

3. Press

ENTER (RESET)”

. The following screen

will be displayed:

DELAY OFF: 0:10

ENTER TO CHANGE

a. To change the circulator-off delay after a call for

heat ends, press

ENTER (RESET)”

. The

following screen will be displayed.

DELAY OFF: 0:10

CHANGE AND ENTER

The time displayed is the current setting in

minutes:seconds.

Press the

“▲”

and

“▼”

keys to select the

desired setting a press

“ENTER (RESET)

.

DELAY OFF: 0:10

ENTER OR CANCEL

Press

ENTER (RESET)”

if the value is correct,

or

CANCEL (BACK)”

if it is not.

b. To change the circulator-on delay when a call for

heat begins, press the

“▲”

and

“▼”

keys until the

following screen is displayed:

DELAY ON 0:10

ENTER TO CHANGE

The time displayed is the current setting in

minutes:seconds.

Press

ENTER (RESET)”

. The following screen

will be displayed.

DELAY ON: 0:10

CHANGE AND ENTER

Press the

“▲”

and

“▼”

keys to select the

desired setting and press the

ENTER

(RESET)”

key.

DELAY ON: 0:10

ENTER OR CANCEL

Press

ENTER (RESET)”

if the value is correct,

or

CANCEL (BACK)”

if it is not.