Aquasmart boiler control manual – Beckett 7600 AquaSmart Boiler Control User Manual

Page 21

Advertising
background image

21

AquaSmart Boiler Control Manual

L2 L1 C1 C2 ZC ZR B1 B2

TR

TW

SK10024

6

5

4

3

2/N

1/H

T

T

ZONE

RELAY

LOW VOLTAGE

THERMOSTAT

ZONE

1

ZONE

RELAY

T

T

1/H

2/N

3

4

5

6

NEUTRAL

HOT

120 VAC

BLACK

WHITE

P1

CIRCULATOR

120 VAC

P3

CIRCULATOR

120 VAC

4

3

2/N

1/H

T

T

ZONE

RELAY

ZONE

2

LOW VOLTAGE

THERMOSTAT

LOW VOLTAGE

THERMOSTAT

ZONE

3*

ZONE

RELAY

T

T

1/H

2/N

3

4

5

6

CIRCULATOR

120 VAC

P4*

CIRCULATOR

120 VAC

P2

DHW

LIMIT

CONTROL

7600A:

120 VAC BURNER

OR GAS IGNITION

SYSTEM

7600B:

24 VAC GAS

IGNITION SYSTEM

FIELD/MFR.

SUPPLIED

SERVICE

SWITCH

5

6

Figure 16 (continued) - 7600A/B multi-zone connections

with Indirect Domestic Hot Water (DHW)

◄ CONTINUED FROM PREVIOUS PAGE

Control Wiring (Option 2): Circulator-On Delay on All Zones

1. Set “DHWP OFF” (default, see programming section for instructions)
2. Set “C1 on ZR” (see programming section for instructions)
3. Circulator-on delay will affect all zones. Circulator-off delay will have

no effect.

4. DHW zone will not have priority over heating zones.

CONTINUED ON NEXT PAGE ►

* Additional zones can be added by duplicating

the plumbing and wiring of zone 3.