Aquasmart boiler control manual – Beckett 7600 AquaSmart Boiler Control User Manual

Page 15

Advertising
background image

15

AquaSmart Boiler Control Manual

TR

TW

SK10032

6

5

4

3

2/N

1/H

T

T

ZONE

RELAY

ZONE

1

LOW VOLTAGE

THERMOSTAT

LOW VOLTAGE

THERMOSTAT

ZONE

2

ZONE

RELAY

T

T

1/H

2/N

3

4

NEUTRAL

HOT

120 VAC

BLACK

WHITE

P1

CIRCULATOR

120 VAC

P3*

CIRCULATOR

120 VAC

6

5

4

3

2/N

1/H

T

T

ZONE

RELAY

ZONE

3*

LOW VOLTAGE

THERMOSTAT

L2 L1 C1 C2 ZC ZR B1 B2

7600A:

120 VAC BURNER OR

GAS IGNITION SYSTEM

7600B:

24 VAC GAS

IGNITION SYSTEM

FIELD/MFR.

SUPPLIED

SERVICE

SWITCH

P2

CIRCULATOR

120 VAC

6

5

Figure 13 (continued) - 7600A/B multi-zone connections

with or without a tankless coil

Control Wiring (Option 2): Circulator-On Delay on All Zones

1. Set “DHWP OFF” (default, see programming section for instructions)
2. Set “C1 on ZR” (see programming section for instructions)
3. Circulator-on delay will affect all zones. Circulator-off delay will have no effect.

CONTINUED FROM PREVIOUS PAGE

* Additional zones can be added by duplicating

the plumbing and wiring of zone 3.