Features table of contents – Beckett 7600 AquaSmart Boiler Control User Manual

Page 2

Advertising
background image

2

HeatManager™ dynamic temperature reset for
additional energy savings
— DOE 2012 Compliant

— Meets NR CAN proposed 2012 requirements

Advanced microprocessor-based design

Backlit LCD digital display with installer
programming touch pad

Quick access to system cycle history

Onboard power disconnect switch (optional)

High/Low limit and High/Low differential
adjustments

24Vac Thermostat compatible

Circulator control - 120Vac

Zone Control - 120Vac (programmable priority
override for domestic hot water)

Temperature sensor mounts in standard
immersion wells

Compatible retrofit for most standard boiler
temperature controls

Programmable circulator-on and -off delays

Helps prevent freeze-up by energizing circulator
and ZC if an error condition is detected.

Periodically exercises circulator pump to help
prevent sieze-up.

Cold-start compatible

6-pin vent damper receptacle on 7500B for easy
wiring to most vent dampers.

Features

Table of Contents

Technical Specifications ............................................. 3

Electrical Ratings ..........................................................................

3

Temperature Ranges and Differentials ..........................................

3

Environmental Ratings ..................................................................

3

Approvals ......................................................................................

3

Installation .................................................................... 4

Mounting .......................................................................................

4

AquaSmart Models and Cross-Reference Guide ..........................

5

Removing the Control to be Replaced ..........................................

7

Installing the Temperature Sensor ................................................

7

Installing the 2-in-1 Sensor ...........................................................

8

Test the Low Water Cut-off (LWCO) Safety Function ................

10

Installing the AquaSmart Control .........................................................

11

Wiring ......................................................................... 11

Wiring the AquaSmart Control ....................................................

12

Programming Basic Functions ................................ 26

A. Temperature High Limit ..........................................................

26

B. Temperature Low Limit...........................................................

26

C. Temperature High Limit Differential .......................................

26

D. Temperature Low Limit Differential ........................................

27

Programming Additional Options ............................ 27

A. Changing the Heat Manager Settings ....................................

27

B. Viewing the Boiler Cycle History ............................................

27

C. Changing the Circulator Settings ...........................................

28

D. Changing Domestic Hot Water Priority (DHWP) Setting .......

29

E. Selecting Fahrenheit or Celsius Temperature Display ...........

29

F. Changing Low Water Cut-Off (LWCO) Setting .......................

29

AquaSmart Operation ............................................... 31

Control Checkout Procedure ......................................................

31

How a Boiler Control Works .......................................................

32

Display Boiler Status Mode ........................................................

33

Troubleshooting ........................................................ 33

Lockout .......................................................................................

33

HeatManager Technology ......................................... 33
Final Checklist ........................................................... 34
Accessories ............................................................... 34
Service ........................................................................ 34
Mounting Template .................................................... 35
Limited Warranty Information .................................. 36

Electrical Shock, Fire,

Explosion and Burn

Hazards

This control must be installed, adjusted and

put into operation only by a trained, licensed,

qualified professional or service agency in

accordance with the National Electric Code

ANSI/NFPA 70 (Canada CSA C22.1) state, local

codes and authorities having jurisdiction.

y

The installer must carefully read and follow the

installation and service instructions contained in this

manual and make them available to the equipment

owner, so they can be kept for future reference.

y

This product is not suitable for temperature control

of pools, spas, or Jacuzzis.

y

This product is not to be used as a step or a shelf.

Advertising