F. changing low water cut-off (lwco) setting – Beckett 7600 AquaSmart Boiler Control User Manual

Page 29

Advertising
background image

29

AquaSmart Boiler Control Manual

c. To change the call for heat source that the

circulator is activated from (see

Figures 8 - 13

for examples), press the

“▲”

and

“▼”

keys until

the following screen is displayed:

CIRC: ON TT
ENTER TO CHANGE

Press

“ENTER (RESET)

to toggle the circulator

source between ON TT, ON ZR, and ON BOTH.

4. Press

CANCEL (BACK)”

to exit.

D. Changing Domestic Hot Water Priority

(DHWP) Setting

The Domestic Hot Water Priority function temporarily

overrides the HeatManager Dynamic Temperature Reset

functionality when there is a call for domestic hot water.

This ensures that hot water will be produced when

needed. It also temporarily turns off either the C1 or ZC

outputs (depending on the DHWP and circulator source

settings) to give priority to the DHWP zone when it calls

for heat. See

Figures 8-13 for examples of how to use

these settings for maximum benefit.

1. In any mode other than an OPTION sub-menu, press

the

“OPTION

key. The following screen appears:

HEAT MANAGR MENU

ENTER TO VIEW

2. Press the

“▲”

and

“▼”

keys until the following

screen is displayed:

MORE OPTIONS

ENTER TO VIEW

3. Press

“ENTER (RESET)

. The following screen

will be displayed:

LWCO MENU

ENTER TO VIEW

4. Press the

“▲”

and

“▼”

keys until the following

screen is displayed:

DHWP: OFF

ENTER TO CHANGE

5. Press

“ENTER (RESET)

to toggle between OFF,

ON TT, and ON ZR settings. See wiring diagrams in

Figures 11 thru 13 for proper wiring with DHWP on.

6. Press

CANCEL (BACK)”

to exit.

E. Selecting Fahrenheit or Celsius

Temperature Display

1. In any mode other than an OPTION sub-menu, press

the

“OPTION

key. The following screen appears:

HEAT MANAGR MENU

ENTER TO VIEW

2. Press the

“▲”

and

“▼”

keys until the following

screen is displayed:

MORE OPTIONS

ENTER TO VIEW

3. Press

“ENTER (RESET)

.

The following screen

will be displayed:

LWCO MENU

ENTER TO VIEW

4. Press the

“▲”

and

“▼”

keys until the following

screen is displayed:

DEG

(F/C):

F

ENTER TO CHANGE

5. Press

“ENTER (RESET)”

to toggle between °F and °C.

6. Press

CANCEL (BACK)”

to exit.

F. Changing Low Water Cut-Off (LWCO)

Setting

The Low Water Cut-off function is active when the 2-in-1

sensor is used with the AquaSmart control to prevent the

burner from firing without sufficient water present in the

boiler. The DELAY OFF time can be selected to delay

the response of the control to a low-water condition. The

DELAY ON time can be selected to delay the response

of the control when the boiler water returns to a sufficient

level. The RESET function can be set to AUTO or MAN

(manual) to control how the AquaSmart will return from a

LOCKOUT LOW WATER condition when the boiler

water returns to a sufficient level. In AUTO, the

AquaSmart returns automatically. In MAN (manual), the

ENTER(RESET)

button must be held for 5 seconds.

1. In any mode other than an OPTION sub-menu, press

the

“OPTION

key. The following screen appears:

HEAT MANAGR MENU

ENTER TO VIEW