D10 and D100 Series Conversion To SkyView Guide – Rev D

Page 16

Guidelines for Conversion of Dynon Avionics EFIS Harness to
SkyView Display SV-HARNESS-D37

As previously mentioned, the EFIS Primary Wiring Harness cannot be adapted for use a SkyView
system, and will be removed from the aircraft. This chart explains the signals and wires
connected to the EFIS Primary Wiring Harness connecting to other devices that must be
rerouted to a SV-HARNESS-D37.

EFIS D25
Female
Connector
Pin No.

EFIS D25
Connector
Wire
Color

EFIS Function

Notes for conversion to SkyView SV-HARNESS-D37

1

RED

MASTER POWER

A single power wire (typically 22 AWG) used for power
to a Dynon Avionics EFIS is inadequate for a (and
especially multiple) SkyView display(s).
Not used in SkyView system.
Remove this wire.

2

YELLOW
(or no
wire in
Dynon
harness)

(FORMERLY) KEEP
ALIVE

Not used in SkyView system.
Remove this wire.

3

BLACK

MASTER GROUND

A single Ground wire (typically 22 AWG) used for
Ground to a Dynon Avionics EFIS is inadequate for a
(and especially multiple) SkyView display(s).
Not used in SkyView system.
Remove this wire.

4

GREEN

DSAB A

DSAB superseded by SkyView Network (new wiring).
Not used in SkyView system.
Remove these wires.

5

BLUE

DSAB B

6, 7, 8

These pins are not used, and thus not populated in the EFIS Connector – no wires.

9

BLACK

SERIAL 1 – GROUND

If this wire was used for connection to PC, no longer
required; remove this wire.
If this wire was used for connection to GPS or NAV
radio, reroute this wire to SkyView Display Master
Ground, common with SV-HARNESS-D37 black wires
on Pins 21 & 22