Page 22

EMS D37
Female
Connector
Pin No.

EMS D37
Connector Wire
Color

EMS Function

SV-EMS-220
Function

Sensor / Wiring Conversion To
SV-EMS-220

9

BROWN/BLUE

CONTACT 1

GENERAL
PURPOSE INPUT
5 (TYPE A)

No changes required.

10

BROWN/YELLOW

CONTACT 2

GENERAL
PURPOSE INPUT
6 (TYPE A)

No changes required.

11

ORANGE

SERIAL A TX

GENERAL
PURPOSE INPUT
7 (TYPE A)

New capability – now a General
Purpose input. Cut off the 9-pin
connector to use this wire.

If connected to EMS Streaming
Data, reroute this wire to
SkyView Display Serial Port TX.

12

YELLOW

SERIAL A RX

GENERAL
PURPOSE INPUT
8 (TYPE A)

New capability – now a General
Purpose input. Cut off the 9-pin
connector to use this wire.

13

BLACK

GROUND

SIGNAL
GROUND

No changes required.

14

YELLOW

FUEL FLOW

FUEL FLOW 1

No changes required.

15

RED

+12V OUTPUT

+12V OUTPUT

No changes required.

16

BLACK

GROUND

SIGNAL
GROUND

No changes required.

17

BLACK

GROUND

SIGNAL
GROUND

No changes required.

18

WHITE/RED

+5V OUTPUT

+5V OUTPUT
(0.5A MAX)

Remove any resistors
connected between this pin
and other pins (pull-ups), esp.
Pin 4, Pin 22, Pin 23 (EMS
General Purpose Inputs – see
notes on those pins.)