Dynon Avionics D100 Series to SkyView Conversion Guide User Manual

Page 20

Advertising
background image

D10 and D100 Series Conversion To SkyView Guide – Rev D

Page 20

EMS D37
Female
Connector
Pin No.

EMS D37
Connector Wire
Color

EMS Function

SV-EMS-220
Function

Sensor / Wiring Conversion To
SV-EMS-220

1

RED

EMS-D10
EMS-D100
MASTER POWER

FlightDEK-D180
UNUSED

VOLTMETER 1
(0-30 VOLTS DC)

New capability; now used for
monitoring voltage.
In EMS-D10 and EMS-D100, this
wire provided power input. In
the FlightDEK-D180, power
input was from the 25-pin EFIS
connector, Pin 1.
If connected to avionics power
(EMS-D10, EMS-D100), OK for
that connection to remain. For
a FlightDEK-D180, connect this
wire for monitoring voltage.

2

YELLOW

(or no wire
installed)

EMS-D10
EMS-D100
KEEP ALIVE

FlightDEK-D180
UNUSED

VOLTMETER 2
(0-30 VOLTS DC)

New capability; now used for
monitoring voltage at a second
point in the electrical system.
In EMS-D10 and EMS-D100, this
wire provided KEEP ALIVE
power input. In FlightDEK-
D180, KEEP ALIVE power input
was from the 25-pin EFIS
connector, Pin 2.
If connected to (backup)
avionics power (EMS-D10, EMS-
D100), OK for that connection
to remain. For a FlightDEK-
D180, connect this wire for
monitoring voltage.

3

BLACK

GROUND (FOR
POWER INPUT)

SIGNAL
GROUND

New capability - now a ground
connection available for
connection to sensors.