EMS D37
Female
Connector
Pin No.

EMS D37
Connector Wire
Color

EMS Function

SV-EMS-220
Function

Sensor / Wiring Conversion To
SV-EMS-220

19

WHITE/BLACK

SERIAL B RX

FUEL FLOW 2

New capability – now a second
(differential) fuel flow sensor
input. If connected, SkyView
can display differential fuel
flow.

If connected to GPS or NAV
input, reroute connection to
SkyView display(s) serial port
RX.

20

ORANGE/BROWN

FUEL LEVEL
1 / LEFT

GENERAL
PURPOSE INPUT
9 (TYPE A)

If connected to resistance type
(float) fuel level sensor, no
changes required.

If connected to capacitive type
(voltage output) fuel level
sensor, reroute connection to
Pin 8, Pin 22, Pin 23, or Pin 31.

21

ORANGE/BLUE

FUEL LEVEL
2 / RIGHT

GENERAL
PURPOSE INPUT
10 (TYPE A)

If connected to resistance type
(float) fuel level sensor, no
changes required.

If connected to capacitive type
(voltage output) fuel level
sensor, reroute connection to
Pin 8, Pin 22, Pin 23, or Pin 31.